Summary of Contents for turck RM-97

  • Page 1 Your Global Automation Partner Analog Encoders RM-97/98/115 Manual...
  • Page 2 Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 800 544 7769 | F +1 763 553 0708 | www.turck.com...
  • Page 3: Table Of Contents

    1 Technical details and encoder characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Mechanical values .
  • Page 4: Technical Details And Encoder Characteristics

    Zero point display: 0 … 1° (The measuring range is factory-set and cannot be modified by the user) Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 800 544 7769 | F +1 763 553 0708 | www.turck.com...
  • Page 5: Optional Functions

    Min . measuring range: 22 .5° Zero point display: 0 … 1° (The measuring range is factory-set and cannot be modified by the user) RM-97/RM-98, Output ‘8B’ Output: 0 … 10 VDC Resolution: 12 Bit Max . measuring range: 65536 revolutions Min .
  • Page 6: Electrical Installation

    If possible, mount all cables with traction relief . Check the maximum supply voltage on the device . Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 800 544 7769 | F +1 763 553 0708 | www.turck.com...
  • Page 7: Function And Status Led

    3 Function and status LED The device is equipped with a two-color (green / red) LED displaying status and errors . LED combinations during operation Display Meaning Error cause Addition No LED on No encoder operation Faulty supply voltage . Check the power supply and Encoder is not operational the wiring...
  • Page 8: Led Combinations For Scaling

    CW or CCW direction of rotation according to customer requirement . The reference point is indicated by the LED from 0 … 1° . Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 800 544 7769 | F +1 763 553 0708 | www.turck.com...
  • Page 9: Scaling Function (Optional)

    Scaling function (optional) The encoder is factory-set to a measuring range of 16 revolutions over which the corresponding output signal is scaled linearily . Two scaling inputs (set 1, set 2 - see chapter Terminal assignment) allow the user to define a desired measuring range . The desired measuring range must be >...
  • Page 10: Reference Point Display

    Positive 2 – 1 1 > 2 (CW) Negative 2 – 1 2 > 1 (CCW) Negative Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 800 544 7769 | F +1 763 553 0708 | www.turck.com...
  • Page 11: Limit Switch Function (Optional)

    Limit switch function (optional) Depending on the scaled measuring range, the output signal remains at the last final value of the scaled output signal until the transition through zero . With the limit switch function, the output signal does not remain at the last final value, but it makes a defined jump .
  • Page 12 Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 800 544 7769 | F +1 763 553 0708 | www.turck.com...
  • Page 13 For Application Assistance or for the location of your nearest Turck distributor, call: 1-800-544-7769 Specifications in this manual are subject to change with out notice . Turck also reserves the right to make modifications and makes no guarantee of the accuracy of the information contained herein .