SMC Networks ZSE20B-L Operation Manual page 89

Digital pressure switch
Table of Contents

Advertisement

○Error indication function
This function is to display error location and content when a problem or error has occurred.
Error
Error displayed
Over current
error
Residual
pressure error
Pressurizing
error
System error
Version does not
match
If the error cannot be reset after the above measures are taken, or errors other than above are displayed,
please contact SMC.
Description
The load current applied to the switch
output has exceeded the maximum
value.
During zero clear operation, pressure
greater than ±7% F.S. is present. Note
that the mode is returned to
measurement mode automatically
1 second later. The zero clear range
varies by ±1% F.S. due to variation
between individual products.
Pressure exceeding the upper limit of
the set pressure range is applied.
Pressure exceeding the lower limit of
the set pressure range is applied.
Displayed if an internal data error has
occurred.
Version of master and IO-Link
does not match.
Mismatch because master version is
1.0.
-88-
Measures
Turn the power off and remove the
cause of the over current.
Then supply the power again.
Release the applied pressure to
atmospheric pressure, and retry the
zero clear operation.
Reset applied pressure to a level
within the set pressure range.
Turn the power off and on again.
If the failure cannot be solved,
contact SMC.
Align the master IO-Link version to
the device.
No.PS※※-OMV0006-D