SMC Networks ZSE20B-L Operation Manual page 70

Digital pressure switch
Table of Contents

Advertisement

●Product individual parameters
Index
Sub
Access
∗1
(dec)
index
0x03E8
0
R/W
(1000)
0x03E9
0
R/W
(1001)
0x03EA
0
R/W
(1002)
0x03EB
0
R/W
(1003)
0x03F2
0
R/W
(1010)
Data
Parameter
storage
∗2
Unit
Y
(Selection of
display unit)
NorP
Y
(Selection of
PNP/NPN)
CoL
Y
(Selection of
display color)
diAg
(Selection of
Y
diagnostic
information)
oUt1
(Selection of
Y
OUT1 output
mode)
-69-
Date
Initial value
type
(dec)
∗3
ISE20B-L(-M): 0
ISE20B-L-P: 4
ZSE20B-L(-M): 1
U8
ZSE20B-L-P: 4
ZSE20BF-L(-M): 1
ZSE20BF-L-P: 4
0x01
U8
(1)
0x02
U8
(2)
0x01
U8
(1)
0x00
U8
(0)
Remarks
Setting of display unit
0: MPa
1: kPa
2: kgf/cm
2
3: bar
4: psi
5: incHg (ZSE20B(F) only)
6: mmHg (ZSE20B(F) only)
Setting of switch output specification
0: NPN
1: PNP
Setting of display color
0: red (Constantly red)
1: Grn (Constantly green)
2: 1SoG
(OUT1 turns green at ON)
3: 1Sor
(OUT1 turns red at ON)
4: 2SoG
(OUT2 turns green at ON)
5: 2Sor
(OUT2 turns green at ON)
Sets the diagnostic information bit
of the input process data
0: Unused (Constantly OFF)
1: All errors ON
Product internal failure
Residual pressure error
Device temperature upper limit
exceeded
Measured pressure range
upper limit exceeded
Falls below measured pressure
range lower limit
2: When the following errors occur,
the parameter turns ON
Measured pressure range
upper limit exceeded
Falls below measured pressure
range lower limit
Setting of OUT1 output mode
0: HYS (Hysteresis)
1: Wind (Window comparator)
2: Err (Error output)
3: oFF
No.PS※※-OMV0006-D