SMC Networks ZSE20B-L Operation Manual page 30

Digital pressure switch
Table of Contents

Advertisement

●[F 1] Setting of OUT1
Item
Either hysteresis mode, window comparator mode, error output or
Output mode
output off can be selected.
Reversed output
Selects which type of switch output is used, normal or reversed.
Pressure setting
Sets the ON and OFF point of the switch output.
Appropriate setting of the hysteresis will prevent the switch output
Hysteresis
from chattering.
Delay time
Delay time of the switch output can be selected.
Display color
Selects the output according to the display color.
●[F 2] Setting of OUT2
Same setting as [F 1] OUT1.
●Other parameter settings
Item
[F 3] Digital filter setting
[F 4] Auto-preset function
[F 6] Fine adjustment of display value
[F10] Sub display setting
[F11] Display resolution setting
[F14] Zero cut-off setting
[F80] Power saving mode
[F81] Security code
[F90] Setting of all functions
[F96] Number of pressurizing errors
[F98] Output check
[F99] Reset to default settings
Page
32
Explanation
Page
35
Page
Page
37
Page
38
Page
40
Page
41
Page
47
Page
48
Page
49
Page
50
Page
52
Page
54
Page
55
Page
57
-29-
Default setting
0.00 s
Not used
0%
std (Standard)
1000-split
0.0
OFF
OFF
OFF
-
N/A (normal output)
OFF
Default setting
Hysteresis mode
Normal output
ISE20B
: 0.500 MPa
ZSE20B : -50.0 kPa
ZSE20BF : 50.0 kPa
ISE20B
: 0.050 MPa
ZSE20B : 5.0 kPa
ZSE20BF : 5.0 kPa
1.5 ms or less
OUT1 ON : Green
OUT1 OFF: Red
No.PS※※-OMV0006-D