●Product individual parameters (continued)
Index
Sub
Access
∗1
(dec)
index
0x0403
0
R/W
(1027)
0x0404
0
R/W
(1028)
0x0406
0
R/W
(1030)
0x0424
0
R/W
(1060)
0x044C
0
R/W
(1100)
0x044D
0
R/W
(1101)
0x044E
0
R/W
(1102)
0x044F
0
R/W
(1103)
Data
Parameter
storage
∗2
dtH2
Y
(OUT2 delay
time at ON)
dtL2
Y
(OUT2 delay
time at OFF)
FiL
Y
(Digital filter)
FSC
(Display value
N
fine adjustment
ratio)
Setting of
Y
lower level
screen
During Std
setting
Y
Selection of
display item
During 2
value setting
Y
Selection of
display item
Left side
During 2
value setting
Y
Selection of
display item
Right side
-73-
Date
Initial value
type
(dec)
∗3
0x0000
U16
(0)
0x0000
U16
(0)
0x0000
U16
(0)
0x0000
S16
(0)
U8
0
U8
0
U8
0
U8
1
Remarks
Setting of OUT2 delay time at ON
Setting range
0x0000 ~ 0x1770
(0 ~ 6000) 0.01 s increment
Setting of OUT2 delay time at OFF
Setting range
0x0000 ~ 0x1770
(0 ~ 6000) 0.01 s increment
Setting of digital filter
0x0000 ~ 0x0BB8
(0 ~ 3000) 0.01 s increment
Displayed pressure value can be
adjusted within ±5%R.D.
(-50 ~ 50) 0.1% increments
0: Std
1: dUAL (2 value display)
2: o1Lv (OUT1 level bar)
3: o2Lv (OUT2 level bar)
4: LinE (Line name)
5: oFF (No display)
Refer to Table "selection of display
items during std setting".
Refer to Table "Selection of display
items during 2 value setting".