SMC Networks ZSE20B-L Operation Manual page 77

Digital pressure switch
Table of Contents

Advertisement

[Selection of display items during standard setting]
Value
Setting content
0
HYS mode set value
1
HYS mode hysteresis
2
Wind mode lower side set value
3
OUT1
Wind mode upper side set value
4
Wind mode hysteresis
5
Err mode
6
oFF mode
7
HYS mode set value
8
HYS mode hysteresis
9
Wind mode lower side set value
10
OUT2
Wind mode upper side set value
11
Wind mode hysteresis
12
Err mode
13
oFF mode
14
Pressure bottom value
15
Pressure peak value
16
Reservation
17
SW output mode/communication mode display
[Selection of display items during 2 value setting]
Value
Setting content
0
HYS mode set value
1
HYS mode hysteresis
2
OUT1
Wind mode lower side set value
3
Wind mode upper side set value
4
Wind mode hysteresis
5
HYS mode set value
6
HYS mode hysteresis
7
OUT2
Wind mode lower side set value
8
Wind mode upper side set value
9
Wind mode hysteresis
10
Pressure peak value
11
Pressure bottom value
12
Reservation
13
Pressure display unit
14
Range specification
15
OUT1 output mode/output style
16
OUT2 output mode/output style
17
NPN/PNP output
18
Line name
19
Display OFF (No display)
●: Settable
×: Not settable (negative acknowledge)
Supplemental information
When the value which does not match the OUT∗ output
mode setting is written, acknowledgment is sent and
[Std - - -] is displayed.
Selection of display
items during
2 value setting
Left side Right side
When the value which does not
match the OUT∗ output mode setting
is written, acknowledgment is sent
and [- - -] is displayed.
×
×
×
×
×
×
-76-
Supplemental information
No.PS※※-OMV0006-D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zse20bf-lIse20b-lIse20bZse20bZse20bfZse20 ... Show all