System Configuration and Functions

Upgrading F3SJ for Muting System

1.
Remove the caps of the emitter and receiver.(driver comes with key cap for muting)
2.
Install a muting lamp (external indicator) on either the emitter or the receiver.
3.
Attach the key cap for muting to the emitter/receiver on which the muting lamp (external indicator) was
not installed.
External indicator set
Model F39-A01P
2. 2.
1. 1.
Cap
Muting sensor
The muting sensor is the sensor that is the trigger for temporarily disabling the F3SJ's safety functions.
Through-beam or retro-reflective photoelectric sensors, proximity sensors, or limit switches can be
used as muting sensors. (recommendation: OMRON E3Z series, E2E series, D4N series)Use those
with PNP outputs or N.O. type contacts.
Use the same power source for a muting sensor as that for the light curtain. If different power supply is used, shutdown
of the light curtain power may not be available.
Muting lamp (external indicator)
Because it notifies workers that the muting function is operational, the muting lamp (external indicator)
must be installed. Use the F39-A01P -PAC or an F39-JJ3N universal indicator cable and a
commercially available external indicator.
Recommended External Indicators p.59
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
F3SJ-A
32
User's Manual
Muting lamp (external indicator)
-PAC
Commercially
available
indicator
Universal indicator
cable
Model F39-JJ3N
Brown: +, Blue: -

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles

3. 3.
Key cap for muting
Model F39-CN6
1. 1.
Cap