External Test Function

This function forcibly stops the emission using an external signal. It can be used to verify that a safety
system should properly stop when F3SJ is interrupted.
To stop the emission, apply 9 to 24V to the emitter's test input line. The voltage must be applied for a
period 4 times that of Toff or longer.
H
Test input
L (Open)
ON
Safety output
OFF
Ton: Response time of safety output's OFF to ON, Toff: Response time of safety output's ON to OFF
Response time p.14
Operation of the F3SJ's indicators when external test function is performed
Test indicator blinks when voltage is applied to the test input.

Self-Test Function

The F3SJ performs the self-test when power is turned ON (within 2 second, or 2.2 seconds in case of
series connection) to check for errors. Also, it regularly performs the self-test (within the response
time) while operating.
ON
Power supply
OFF
Within 2 s
(Within 2.2 s)
ON
Self-test
OFF
If an error is found in the self-test, the F3SJ enters lockout state, keeps the safety outputs in the OFF
state, and indicates the error at the same time.
Error indication patterns and causes of errors p.8
How to reset lockout: See p.29 for basic system and p.46 for muting system
For information about lockout, see p.113
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
System Configuration and Functions
Toff x 4 or less
Subsequently performs periodic test
Ton x 2 or less
User's Manual
E
F3SJ-A
27