Basic System; Wiring Diagrams - Omron F3SJ-A P Series User Manual

Hide thumbs Also See for F3SJ-A P Series:
Table of Contents

Advertisement

Basic System

Basic system indicates the F3SJ with its default factory settings.
The basic system provides basic safety light curtain functions. Most functions can be used without performing
additional configuration.

Wiring Diagrams

Wiring using manual reset mode, external device monitoring
Emitter
Receiver
S1
: External test switch
S2
: Interlock/lockout reset switch
K1,K2 : Relay or other device that controls
hazardous parts of the machine
K3
: Load or PLC, etc. (for monitoring)
*1 Use a switch for micro loads (Input specifications: 24V, 2.5mA)
*2 F3SJ operates even when K1 to K3 are not connected
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
+24V DC
(White) Interlock selection input
1
(Brown) 24V
2
(Green) Test input
3
(Yellow) Reset input
4
(Grey)Communication line (+)
5
(Pink) Communication line (-)
6
(Blue) 0V
7
(Red)
8
Shield
(White) Safety output 2
1
(Brown) 24V
2
(Green) Safety output 1
3
(Yellow) Auxiliary output 1
4
(Grey)Communication line (+)
5
(Pink) Communication line (-)
6
(Blue) 0V
7
(Red) External device monitoring input
8
Shield
0V
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles
System Configuration and Functions
S1
S2
*1
*1
Open
*2
*2
*2
K3
K1
K2
K1
K2
E
F3SJ-A
23
User's Manual

Advertisement

Table of Contents
loading

Table of Contents