The output command subsystem is used to control the output state of the power source.
The following measurement commands are supported.
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
MEASure:LOGger:TIMEstamp <cr>
Sets the time stamp format that will be attached to every
measurement record in the measurement log file.
< DATE | 0 | TIME | 1 | ALL | 2 >
<cr>
MEAS:LOG:TIME ALL
MEASure:LOGger:TIMEstamp?
<nr1>
MEAS:LOG:TIME?
2
OUTPut:FAST <b>
Enable or disable fast energy savings startup mode (STANDBY mode)
when output is closed. This mode does not completely shut down all
inverters for energy savings while the output is off. This allows near
immediate application of output to the load when the output
command is received. When disabled, there is delay of 2.2 seconds to
allow all power stages to start up and settle in.
< 0 | OFF | 1 | ON >
<b>
OUTP:FAST ON
OUTPut:FAST?
<b>
OUTP:FAST?
1
AFX SERIES® OPERATION MANUAL