Csc Configuration Screen; Table 6-18: Available Slew Rate Settings Screen Soft Keys - Pacific Power Source AFX Series Operation Manual

Hide thumbs Also See for AFX Series:
Table of Contents

Advertisement

The soft keys on the PROGRAM MEMORY screen provide access to additional functionality
as listed in the table below.
SOFT KEY
Browse(SK1)
Recall (SK2)
Save (SK3)
Set (SK4)
Refresh (SK5)
6.7.5

CSC CONFIGURATION Screen

The CSC CONFIGURATION menu allows the Continuous Self Calibration mode to be
enabled. This mode will use the internal measurements to adjust the output voltage
continuously so it matches the programmed setting. If the CSC is unable to get the output to
the set point, an error will be generated. This error can be disabled by unchecking the "Fault
on saturation" check box.
The soft keys on the CSC CONFIGURATION screen are listed in the table below
SOFT KEY
-
-
-
-
Back (SK5)
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Description
Allows browsing for a particular register's content.
Recalls selected Register setup content
Saves setup to selected Register
Sets output to selected Register content
Refreshes screen

Table 6-18: Available SLEW RATE SETTINGS screen soft keys

Figure 6-20: CSC CONFIGURATION screen
Description
Refreshes screen