[35] Restoral Reporting Codes, Zones 1 - 8

These reporting codes are used by the communicator to transmit zone restorals for zones 1 through 8. Program 8
2-digit numbers in this section.

[36] Closing (Arming) Reporting Codes for Access Codes 1 - 8

Reporting codes 1 to 8 are used to identify closings for Access Codes 1 to 8. If partial closing is identified in
Section [46], then alarm codes for manually bypassed zones will be transmitted with the partial closing code
when the system is closed with one or more zones bypassed.
When transmitting in 4/2, 3/1 or any other of the extended formats, refer to Section [34] for transmission
information. The 8 closing codes are programmed as follows:
Where the first digit HEX 'C' represents a closing signal and the second digit represents the user Access Code which
was used to arm the system (HEX 'C' could be any other number depending on what is used at the monitoring station).
The closing code transmission takes place after the exit delay time. Therefore, if the system is armed and
disarmed before the expiry of the exit time, no closing transmission will take place.
The partial closing code, if used, is transmitted in tandem with the regular closing code to identify the closing as a
partial closing. When the system has been armed using the Quick-Arm command [
Access Code 1 will be transmitted.

[37] Opening (Disarming) Reporting Codes for Access Codes 1 - 8

These 8 reporting codes correspond to the 8 Access Codes. When the system is disarmed using one of the
Access Codes, the corresponding reporting code in this section is transmitted.
If the After Alarm Code is programmed, that code will be transmitted to the monitoring station on opening if an
alarm occurred during previous armed period. This feature is useful for installations where openings and closings
are not reported normally, but it is desired to have a report to the monitoring station on opening if an alarm did
occur during the previous armed period. This feature allows the monitoring station to know when the user is on
the premises and available to receive a report about alarms while the system was closed.

[38] Priority Alarms and Restorals

These reporting codes are used by the communicator to transmit the following list of troubles, alarms and
restorals:
• Keypad [F]ire alarm
• Keypad [A]uxiliary alarm
• Keypad [P]anic alarm
• 2-Wire Smoke Detector alarm
Transmission for operation of the [F], [A] and [P] keys will only take place if codes are programmed in Section [38].

[39] Maintenance Alarm Reporting Codes

These reporting codes are used by the communicator to transmit the following list of alarms and restorals.
• Battery Trouble Alarm
• AC Failure Trouble Alarm
• Bell Circuit Trouble Alarm
• Fire Trouble Alarm

[40] Maintenance Restoral Reporting Codes

These reporting codes are used by the communicator to transmit the following list of alarms and restorals.
• Battery Trouble Restoral
• Bell Circuit Trouble Restoral
• Fire Trouble Restoral

[41] LINKS1000 Maintenance Reporting Codes

Program the TLM Trouble Code and the LINKS1000 Test Transmission Code in this Section. If a LINKS1000 is
not connected to the system, these codes must not be programmed.
20
[C1], [C2], [C3], [C4], [C5], [C6], [C7], [C8]
• Keypad [F]ire restore
• Keypad [A]uxiliary restore
• Keypad [P]anic restore
• 2-Wire Smoke Detector restoral
• Auxiliary Power Supply Trouble Alarm
• Periodic Test Transmission
• System Test
• Auxiliary Power Supply Trouble Restoral
• Periodic Test Transmission
• TLM Restoral