Natural Gas Requirements
Verify the type of gas your grill has been configured for by the factory by checking the serial tag
inside the door of the grill cabinet. Grills configured for natural gas (NG) are orificed differently than
grills configured for liquid propane (LP) gas. Grills configured for use with natural gas are shipped
with a gray hose with a quick-connect fitting.
Connection: 1/2" NPT male. Quick-connect hose assembly (included) connects to the grill via a
0.625" flare fitting.
Input Pressure: 7.0" W.C. (17.4 mbar)
Manifold Pressure: 4.0" W.C. (10 mbar)
7" W.C. NATURAL
GAS SUPPLY
SUPPLY END
INSTALLER-SUPPLIED SHUT-
OFF VALVE WITH 1/2" MALE
NPT CONNECTION FOR GRILL
FIGURE 6
12
INCLUDED 4" W.C. REGULATOR
INCLUDED BRASS FITTING CONNECTS
INCLUDED REGULATOR TO INCLUDED
QUICK-CONNECT FITTING
INCLUDED QUICK-CONNECT
FITTING AND 10' FLEXIBLE
GAS HOSE
GRILL END
INCLUDED 10' FLEXIBLE
GAS HOSE CONNECTS TO
GRILL WITH FLARE FITTING
(NO PIPE SEALANT
NEEDED HERE)
FITTING ON GRILL CAN BE
ROTATED 90° STRAIGHT
DOWN IF PREFERRED