For the DTP ports only —
Extron recommends the following practices to achieve full transmission distances up to 330
feet (100 m) and reduce transmission errors.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000
XTP DTP 24P/1000
XTP DTP 24 Plug
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA T568B standard only (patch
cables, see
figure 7
Limit the use of more than two pass-through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass-through points are required,
use CAT 6 or 6a shielded couplers and punch down connectors.
ATTENTION:
Do not connect these boards to a computer data or telecommunications network.
Ne connectez pas ces port à des données informatiques ou à un réseau de télécommunications.
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable to link the
matrix switcher to Extron DTP products, XTP matrix switchers, or HDBaseT-enabled devices.
N'utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF-4 ou le câble STP201 pour
relier la grille de commutation aux produits DTP, aux grilles de commutation XTP ou aux appareils
équipés HDBaseT Extron.
To ensure FCC Class A and CE compliance, STP cables and STP connectors are required.
Afin de s'assurer de la compatibilité entre FCC Classe A et CE, les câbles STP et les connecteurs
STP sont nécessaires.
NOTE: When using cable in bundles or conduits, consider the following:
Do not
exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened, aligned, and secured
in tight bundles.
Loosely place cables and limit the use of tie wraps or hook and loop fasteners.
Separate tw
DTP CrossPoint 84 • Installation
Non-Plenum 1000' (305 m) spool
Plenum 1000' (305 m) spool 22-235-03
Package of 10
on page 9).
isted pair cables from AC power cables.