Troubleshooting - ProLights ARCLED3144RGBWA User Manual

Architainment led projector
Table of Contents

Advertisement

Available languages

Available languages

20

4.3 TROUBLESHOOTING

Problems
Fixture does not light up
General low light intensity
Fixture does not power up
Fixture does not respond to DMX
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.
ARCLED3144RGBWA
Possible causes
No mains supply
Dimmer fader set to 0
All color faders set to 0
All colors in STATIC are seto to 0
Faulty LED
Faulty LED board
Dirty lens assembly
Misaligned lens assembly
No power
Loose or damaged power cord
Faulty internal power supply
Wrong DMX addressing
Damaged DMX cables
Bouncing signals
Checks and remedies
Check the power supply voltage
Increase the value of the dimmer channels
Increase the value of the color channels
Increase the values og the colors
Replace the LED board
Replace the LED board
Clean the fixture regularly
Install lens assembly properly
Check for power on power outlet
Check power cord
Replace internal power supply
Check control panel and unit addressing
Check DMX cables
Install terminator as suggested

Advertisement

Chapters

Table of Contents
loading

Table of Contents