Page 1
ARCSPOT XL VW IP66 Spot featuring 12300 lumen with 61x 4W Variable White source, 10° native USER MANUAL English version REV.01-02/24 PRELIMINARY...
Page 2
PROLIGHTS product are trademarks OWNED or licensed by Music & Lights S.r.l., its affiliates, and subsidiaries. PROLIGHTS is a registered trademark by Music & Lights S.r.l. All right reserved. Music & Lights – Via A. Olivetti, snc - 04026 - Minturno (LT) ITALY.
LENS (CODE ASLENS15/25/45 - OPTIONAL) ..............22 BRACKET FOR WALL MOUNTING AND SUSPENSION ON POLES (CODE MOSUNIBRACKJR) ......................25 13 - MAINTENANCE MAINTENANCE AND CLEANING THE PRODUCT............26 VISUAL CHECK OF PRODUCT HOUSING ..............26 14 - TEST OF IP66 RATING PROLIGHTS - ArcSpot XLVW...
• Do not reapply power until repairs have been completed. • Refer any service operation not described in this manual to PROLIGHTS Service team or an authorized PROLIGHTS service center.
Page 5
• Warning! Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling. • Only technicians who are authorized by PROLIGHTS or Authorised service partners are permitted to open the fixture. • Users may carry out external cleaning, following the warnings and instructions pro- vided, but any service operation not described in this manual must be referred to a qualified service technician.
Page 6
• This device complies with Part 15 of the FCC Rules. Operation is subject to the fol- lowing two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. PROLIGHTS - ArcSpot XLVW...
Check the updated accessories list, description and informations of the product at the following link: https://www.prolights.it/product/ARCSPOTXLVW#accessories 2 - TECHNICAL DRAWING 339mm 153mm 310mm [13.3in] [6.0in] [12.2in] Ø397mm [15.6in] Fig. 01 Weight: 11,9 kg - 26,23 lbs PROLIGHTS - ArcSpot XLVW...
NOTE: In external installations it is advisable to mount the product with the cables facing downwards to avoid water or humidity deposits which can compromise functionality in the long term. C6002 RSR1235B clamp Steel security cable 42mm 100mm 3xØ13mm [1.7in] [3.9in] [Ø0.5in] Fig. 02 PROLIGHTS - ArcSpot XLVW...
• Connect the power connector into the Mains input socket (100-240 VAC-50/60 Hz). • The product is then ready for its operations and can be controlled through the available input sig- nals on board. • To disconnect power from the product, disconnect the Mains from the socket. PROLIGHTS - ArcSpot XLVW...
Install a DMX termination plug on the last fixture on the link. If a splitter is used, terminate each branch of the link. NOTE: when not using the DMX input or DMX output connectors, you must seal the cable ends with the supplied caps. PROLIGHTS - ArcSpot XLVW...
The termination is prepared by soldering a 120Ω 1/4 W resistor between pins 2 and 3 of the male XLR connector, as shown in figure. Pin1 : GND - Shield (Black) Pin2 : - Signal (Yellow) Pin3 : + Signal (Red) Pin4 : Auto-addressing (White) Example: 5 pin XLR connector Fig. 07 PROLIGHTS - ArcSpot XLVW...
... . DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX OUT DATAMASTER Fig. 04 - Example 12 DMX channels configuration Fig. 08 PROLIGHTS - ArcSpot XLVW...
To see the unit temperature. TEMP, DRIVER PCB TEMP, LED PCB TEMP,… SOFTWARE View informations about software VERSION version. DEVICE INFO View informations about device. DEVICE LABEL Show RDM Device label. RDM UID View ID for the RDM control. PROLIGHTS - ArcSpot XLVW...
Page 15
5600K 6000K 6500K MANUAL WARM WHITE DIMMER:0-255 User generated color preset by assigning values to each primary color attribute. After enabled this mode, the unit will be COLD WHITE DIMMER:0-255 automatically assigned as Master. FACTORY DEFAULT PROLIGHTS - ArcSpot XLVW...
Page 20
Default @ 0 Warm White 8 bit value 16 bit value Function Note From From DIMMER Default @ 255 Cold White 8 bit value 16 bit value Function Note From From DIMMER 65535 Default @ 255 PROLIGHTS - ArcSpot XLVW...
Page 21
DMX FAULT STAND ALONE STAND ALONE MASTER DMX STAND ALONE MASTER NO DMX STAND ALONE SLAVE STAND ALONE EFFECTS STAND ALONE FIXED COLORS STAND ALONE WHITE PRESETS STAND ALONE MANUAL CW+WW RESERVED RESET ALL CHANNEL CONTROLLED RESERVED PROLIGHTS - ArcSpot XLVW...
LENS (CODE ASLENS15/25/45 - OPTIONAL) Place fixture on a stable surface. • Remove the rubber caps (A), then unscrew the metal front ring screws (B). • Remove the metal front ring (C). Fig. 12 PROLIGHTS - ArcSpot XLVW...
Page 25
Turn the fixture with lenses upside and proceed as follows: • Unscrew the lenses holder screws (D). • Remove the lenses holder (E). NOTE: be careful to match the spaces in the same way as they are disassembled to close the product correctly. Fig. 12 PROLIGHTS - ArcSpot XLVW...
Page 26
Gently replace each lens as shown in figure, Fig. 12 PROLIGHTS - ArcSpot XLVW...
BRACKET FOR WALL MOUNTING AND SUSPENSION ON POLES (CODE MOSUNIBRACKJR) NOTE: Do not mount the bracket on a support whose surface shows deformations, injuries, crushing, etc. Both the bracket and the unit must be secured with a safety cable. Fig. 12 PROLIGHTS - ArcSpot XLVW...
IP grade of the fixture. • All other service operations on the product must be carried out by PROLIGHTS, its approved service agents or trained and qualified personnel.
It is recommended to verify IP grade using IPTESTBOX every time the bodies are removed for maintenance. Remove the gore valve from the rear cover. Connect the air hose to the IPTESTBOX by inserting the quick-connect fitting into the coupler. PROLIGHTS - ArcSpot XLVW...
Page 30
Insert the threaded end into the threaded valve hole socket. For the operating procedure using the instrument, refer to the IPTESTBOX user manual. PROLIGHTS - ArcSpot XLVW...