Programming Opening, Closing Times And Gate Pause - FAAC E012 Instruction Manual

Table of Contents

Advertisement

Rev. 01.2006 - Istallation Manual
Page 13
2.5.3

PROGRAMMING OPENING, CLOSING TIMES AND GATE PAUSE

During this stage, the control unit memory stores work time and any pause time.
To access programming, follow the instructions below:
1-
Release the operators (see the instructions on the mechanical operators) and take the leaves to about
halfway of the opening travel.
2-
Relock the operators (see the instructions on the mechanical operators) and power up the system.
3-
Turn ON dip-switch 8 on the control unit. The flashing lamp lights up on steady beam to indicate entry
to the programming procedure.
4-
Give a total opening pulse with the "START" push-button or with the radio control (if already memory
stored) and the leaves will begin to move.
The first manoeuvre the control unit carries out is closing.
5-
Make sure that both leaves perform the closing manoeuvre and that the leaf with motor M2 moves
first.
If this does not happen, stop gate movement with a "RESET" pulse, jumper connecting the two
"RESET" pins to each other and using the connector (see figure).
6-
Cut the power supply and take the connector back to its normal position (see figure).
7-
Make the suitable corrections to the motor connections, and repeat from point 4, changing over the
cables of the motors on connector CN2 (see paragraph 2.3.).
8-
When they reach the closing mechanical stop point, the leaves pause for two seconds, and then begin
the opening stage
9-
When both leaves reach the opening mechanical stop point, the pause time count begins.
10- When the required pause time has elapsed, give a total opening pulse.
The leaves begin the closing stage.
11- When the leaves reach the closing stop, programming has finished.
12- Turn OFF dip-switch 8 - the flashing lamp goes OFF to finish programming.
R E S E T
CONNECTOR
NORMAL
R E S E T

Advertisement

Table of Contents
loading

Table of Contents