Connection Of (Optional) Batteries - FAAC E012 Instruction Manual

Table of Contents

Advertisement

Rev. 01.2006 - Istallation Manual
Page 11
2.4.1

CONNECTION OF (OPTIONAL) BATTERIES

Terminals "+ BAT - BAT". Connect the 2 optional batteries to terminals "+ BAT - BAT".
During normal operation, the control unit keeps the batteries charged.
The batteries come into operation when the transformer does not supply power.
During connection, respect the polarity indicated on the board.
A maximum of two 12 Vdc - 1.2 Ah batteries, connected in parallel, can be connected to the control unit.
Power supply provided by the batteries should be considered an emergency situation.
The number of possible manoeuvres depends on the quality of the batteries, the gate's structure
(weight, dimensions, condition of the pivot , etc..), and on the time since power was cut, etc.
BROWN
BROWN
BLUE
BLUE
RED
RED
After installing the
batteries, open the
p r e - p e r f o r a t e d
section in the lower
part of the enclosure.

Advertisement