Download Print this page

PDQ 6300 Installation Instruction

Cvr exit cf devices

Advertisement

Quick Links

CVR EXIT INSTALLATION INSTRUCTION
6300/6400C & CF DEVICES
2. ASSEMBLE RODS &
LATCHES
 Thread CVR linkage into each rod to
approximate middle of threads
Steel/Wood Door – Attach mounting
Aluminum Door –
THRESHOLD NOTE:
When using ½" threshold, move bottom rod
attachment pin to upper hole in bottom rod.
PIN
SLOT
brackets as shown
Continue to next step
TO TOP OF L BRACKET
OR TOP OF LATCH BODY
TOP ROD
BOTTOM ROD
SLOT
CVR
LINKAGE
BOTTOM
ROD HOLES
3. ADJUST RODS
When measuring, be sure length is in the
collapsed pin position as shown.
TOP ROD LENGTH: Measure from top
of door to device centerline. Subtract 2 1/
4".
Typical 7' Door: 41 5/8"
(43 7/8" - 2 1/4" = 41 5/8")
BOTTOM ROD LENGTH: 37" if device
is installed 40" above the finished floor.
PIN
1
Phone: 833-2-PDQTEC | www.pdqlocks.com
1. PREPARE DOOR
 Prepare door according to
template.
 Refer to trim template if
installing trim.
MOUNTING
BRACKETS
639409 Rev1 – 6/15/22
CVR
LINKAGE

Advertisement

loading
Need help?

Need help?

Do you have a question about the 6300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PDQ 6300

  • Page 1 CVR EXIT INSTALLATION INSTRUCTION 6300/6400C & CF DEVICES Phone: 833-2-PDQTEC | www.pdqlocks.com 1. PREPARE DOOR  Prepare door according to template.  Refer to trim template if installing trim. 2. ASSEMBLE RODS & LINKAGE LATCHES  Thread CVR linkage into each rod to...
  • Page 2 CVR EXIT INSTALLATION INSTRUCTION 6300/6400C & CF DEVICES INSIDE OF STEEL/WOOD DOOR DOOR 4. INSTALL LATCHES IN DOOR  Slide latch/rod assemblies into the door. Slide bottom latch into door installed in housing.  Fasten with #8-32 screws. **IMPORTANT NOTE**...
  • Page 3 CVR EXIT INSTALLATION INSTRUCTION 6300/6400C & CF DEVICES Phone: 833-2-PDQTEC | www.pdqlocks.com CARRIAGE 6. INSTALL CVR LIFT BARS ADJUSTING SCREW ADJUSTING SCREW RETAINER  Adjusting screw and retainer factory LOCKING SCREW installed without lift bars.  Remove adjusting screw retainers and adjusting screws.
  • Page 4 CVR EXIT INSTALLATION INSTRUCTION 6300/6400C & CF DEVICES 9. INSTALL TOP STRIKE  Install strike using two #10-24 flat head screws from pack #639054.  With door installed, adjust strike to desired door free play. Recommended is minimum of 1/16".