6300M/MF EXIT INSTALLATION INSTRUCTION
MORTISE DEVICE
LATCH BOLT
HEAD SCREW
LATCH BOLT
HEAD
INSIDE
LEFT HAND REVERSE
(LHR)
OUTSIDE
2. DOOR PREPARATION
 Prepare the door for the mortise lock
using the 6300M/MF template in box.
 Refer to trim template if installing trim.
 Install the mortise case and secure using
two (2) #12-24 combo screws supplied in
the hardware kit.
LATCH BOLT
HEAD SCREW
LATCH BOLT
HEAD
INSIDE
RIGHT HAND REVERSE
(RHR)
OUTSIDE
MORTISE
DRIVER
LOCATING
STUD
THREADED
INSERT
Phone: 833-2-PDQTEC | www.pdqlocks.com
1. MORTISE HANDING
 To re-hand mortise case, remove latch
bolt screw as shown.
 Orient the latch bolt head to match
handing.
 Reinsert and tighten the latch bolt screw.
3. PREPARE DEVICE
 Install locating stud on lower threaded
insert as determined by handing.
 Rotate lower mortise driver as shown
until it stops. Make sure when installing
that mortise driver remains in this
position.
1
639415 Rev0 – 4/22/21

Advertisement

loading
Need help?

Need help?

Do you have a question about the 6300M/MF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PDQ 6300M/MF

  • Page 1 OUTSIDE 2. DOOR PREPARATION  Prepare the door for the mortise lock using the 6300M/MF template in box.  Refer to trim template if installing trim.  Install the mortise case and secure using two (2) #12-24 combo screws supplied in the hardware kit.
  • Page 2 6300M/MF EXIT INSTALLATION INSTRUCTION MORTISE DEVICE 4. SIZE DEVICE  Standard lengths are for 36" or 48" door. Device must be cut for other lengths.  Mark length with tape – length equals device size minus desired door size (for 30"...
  • Page 3 6300M/MF EXIT INSTALLATION INSTRUCTION MORTISE DEVICE Phone: 833-2-PDQTEC | www.pdqlocks.com 7. INSTALL END CAP  Slide end cap into rail. Ensure rail is level. Mark the centers of the slots.  Remove end cap then drill holes using the chart from Step 3.