Wahlberg Roll Down Manual page 24

Table of Contents

Advertisement

POS OUT
This feature enables you to know exactly where the Roll Down is. The position feedback outputs a DMX signal on
pin 1,4,5 of the DMX in/out plugs. All values are zero except for the feedback which is located at the DMX address
of the device. Meaning if the Roll Down has starting channel 73 then the 16bit feedback will be at channel 73 and
74. The menu options are
-
OFF: No output
-
SCALE: 16 bit scaled feedback. The feedback will be 0,0 at the bottom and 255,255 at the top
-
DIV 4: 16 bit raw feedback divided by 4. The feedback will be 0,0 at the bottom and TAC RANGE divided
by 4 at the top. For a 10 meter span this is roughly 77,104.
-
32BIT: 32 bit raw feedback. This feedback will be 0,0,0,0 at the bottom and TAC RANGE at the top. For a
10 meter span this is roughly 0,1,53,161.
UNSAFE MODE
CAUTION!: UNSAFE MODE should only be used in emergency situations. It disables both limit switches, and
emergency stop.
NOM. FREQ
Frequency of the national grid of installation.
REVERSE DIR
Reverse motor movement, encoder, and limit switch direction.
QUICK SLACK
This option has no effect on the Roll Down
PRECISION
The tolerance in which the Roll Down will stop. To small a precision will lead to the Roll Down overshooting its
wanted position and never stop. This will cause the motor to overheat and eventually get damaged.
SLS DIST
Shows how many kilometres the Roll Down has travelled Since Last Service reset (SLS RESET).
SLS TIME
Shows how many hours the Roll Down has been moving Since Last Service reset (SLS RESET).
SLS ON
Shows how many hours the Roll Down has been powered on Since Last Service reset (SLS RESET).
SLS RESET
Set all SLS values to zero. Go through all service steps described in the manual and contact Wahlberg Motion Design
for any spare parts.
TOT DIST
Shows how many kilometres the Roll Down has travelled since production.
TOT TIME
Shows how many hours the Roll Down has been moving since production.
TOT ON
Shows how many hours the Roll Down has been powered on since production.
FACTORY RST
Reset all menu values to its default settings.
249.805.013
Position feedback
Disable all limit switches
Power input frequency
Reverse direction of up and down
Stop quickly when slack activates
Tolerance for settling
Kilometres moved Since Last Service
Hours moving Since Last Service
Hours powered on Since Last Service
Reset Since Last Service parameters
Kilometres moved in total
Hours moving in total
Hours on in total
Reset to factory default settings
24
50/60
OFF/ON
OFF/ON
5 – 100
NO/YES
NO/YES
Date: 2021-12-09

Advertisement

Table of Contents
loading

This manual is also suitable for:

249

Table of Contents