Emergency stop switch (Optional)
WARNING! By default, the emergency stop is NOT enabled!
The Roll Down can be configured with an emergency stop; by default, the emergency stop is not
enabled.
The DMX control from a lighting desk should always have a set up so there is a button that sets
the speed of the Roll Down in operation to 0%. Normally lighting desks have a "blackout" button
that sets all intensity channels to 0% and this will also cause the Roll Down to stop when assigned
correctly.
If the emergency stop switch is activated the red Error LED will be lit and the screen display shows:
'EMERGENCY STOP PRESSED' and the current start channel of the unit:
The emergency stop switch is connected to the male 4 pole XLR connector on the winch. Pin 1 and
Pin 4 should be powered with 12-15 volt DC to enable operation of the winch.
Pin out:
Pin 1
Pin 2
Pin 3
Pin 4
The emergency stop power supply and plug is available for purchase from Wahlberg Motion
Design.
249.805.013
Connection
GND
Not connected
Not connected
12-15 V DV