STEP 1: Remove deter-
gent suction tube from
container and insert into
one gallon of fresh water.
Slide nozzle forward for
low pressure or to connect
black detergent nozzle.
Pull trigger on spray gun
and siphon water for one
minute.
Pump
Water
Inlet
STEP 5: Disconnect the
garden hose from the wa-
ter inlet on the machine.
Pump Storage
CAUTION: Always store your pres-
sure washer in a location where the
temperature will not fall below 32° F
(0° C). The pump in this machine is
susceptible to permanent damage if
CAUTION
frozen.
FREEZE DAMAGE IS NOT COVERED
BY WARRANTY.
If you must store your pressure washer in a location
where the temperature is below 32° F, you can minimize
the chance of damage to your machine by draining your
machine as follows:
10
SHUTTING DOWN AND CLEAN-UP
STEP 2: Turn off machine
by fl ipping switch on rear
of motor or by pressing the
switch on the remote con-
trol box (if equipped).
STEP 6: Disconnect the
high pressure hose from
high pressure outlet.
ZE/ZEF-ET-HD-HE • 8.914-001.0 • 8.941-457.0 • 9.800-088.0 • 8.919-017.0 • Rev. 11/15
STEP 3: Turn off water
supply.
High
Pressure
Outlet
Safety
Latch
STEP 7: Engage the spray
gun safety lock.

STORAGE

1. Stop the pressure washer and detach supply hose
and high pressure hose. Squeeze the trigger of the
spray gun to drain all water from the wand and
hose.
2. Restart pressure washer and let it run briefl y (about
5 seconds) until water no longer discharges from
the high pressure outlet.
STEP 4: Press trigger to
release water pressure.