After Each Operation; Shutdown; Maintenance And Care - Kärcher HDS Super M Eco Instructions Manual

Hide thumbs Also See for HDS Super M Eco:
Table of Contents

Advertisement

Available languages

Available languages

– De-preserve, contaminations contain-
ing strong fat contents
100-110 °C
– De-frosting of surcharge substances,
partially facade cleaning
up to 140 °C

After each operation

Danger
Danger of scalding by hot water. After the
operation with hot water or steam, the de-
vice must be operated with openend gun
with cold water for at least two minutes.
After operation with detergent
Î Set dosing value for detergent to "0".
Î Set the appliance switch to "I".
Î Open the hand spray gun and rinse the
appliance for at least 1 minute.
Turn off the appliance.
Î Set the appliance switch to "0".
Î Shut off water supply.
Î Turn on pump shortly (appr. 5 seconds)
with device switch.
Î Pull main plug out of socket with dry
hands only.
Î Remove water connection.
Î Activate hand spray gun until device is
pressure less.
Î Secure hand spray gun, Figure 8 (A).
Î Lock in the steel pipe into the holder of
the appliance hood.
Î Roll up high pressure hose and electri-
cal conduit and hang them into the re-
spective holders.
Device with hose drum:
Î Before rolling up, stretch out the high
pressure hose.
Î Turn the hand crank clockwise (Direc-
tion of the arrow).
Note
Do not twist high pressure hose and electri-
cal conduit.
28
English
Warning
Frost will destroy the not completely water
drained device.
Î Store in a frost free area.
If the device is connected to a chimney, the
following must be observed:
Warning
Threat of damage by penetrating cold air
through the chimney.
Î Disconnect device from chimney when
outside temperature drops below 0 °C.
If it is not possible to store frost free, shut
down device.

Shutdown

For longer work breaks or if a frost free stor-
age is not possible:
Î Drain water.
Î Flush device with anti-freeze agent.
Î Empty detergent tank.
Dump water
Î Screw off water supply hose and high
pressure hose.
Î Screw off supply hose at boiler bottom
and drain heating spiral empty.
Î Operate device for max. 1 minute until
the pump and conduits are empty.
Flush device with anti-freeze agent
Note
Observe handling instructions of the anti-
freeze agent manufacturer.
Î Fill anti-freeze agent of the trade into
swimmer container.
Î Switch on appliance (without heater) till
the appliance has been completely
rinsed.
A certain corrosion protection is achieved
with this as well.

Maintenance and care

Danger
Risk of injury! Always disconnect the device
from the electrical power supply before per-
forming maintenance or repair work.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Hds super mx ecoHds 695 m ecoHds 895 m ecoHds 1195 s ecoHds 1195 sx ecoHds 695 mx eco ... Show all

Table of Contents