OOR CONTROL
A door control input enables the user to connect safety switches to the
PowerBox and prevent accidental exposures. There are 5 door control
inputs available on the PowerBox, each one of them can be enabled or
disabled individually. The PowerBox will not start an exposure while an
open contact is detected on one of the enabled door control inputs.
All off: Disable all door controls.
Door 1, Door 2, Door 3, Water, Oil: Change the setting for each
individual door.
5.4.3 L
AMP CONTROL
All lamp on the PowerBox front panel, the externally connectable lamp,
siren or buzzer outputs and the warning lamp on the CP SERIES
generator are equipped with a 'device failure' detection. When enabled
the PowerBox will detect a failure of one or more of these devices and
display an error indicating which lamp or buzzer is defect. No X-ray is
emitted while the error condition exists to prevent accidental radiation
due to a failing warning device.
When no external lamps or siren are connected, the device failure
detection can be deactivated in this menu.
All off: Disables the device failure detection for all devices.
Lamp 1, Lamp 2, Lamp 3, Ext Buzzer: Enable/disables the
device failure detection for the external lamp and siren outputs
on the PowerBox's Interlock connector.
Green lamp, Red lamp, Yellow lamp: Enable/disables the device failure detection for the front panel
lamps of the PowerBox.
Gen lamp: Enable/disables the device failure detection CP SERIES generator warning lamp
5.4.4 I
NTERLOCK
This menu allows programming the behavior of each warning device and
output for each of the generator's states: Standby, Pre-warning, Shot,
End of shot, error and preheat.
Operator can choose between 4 pre-sets of behavior
Denmark: warning devices and outputs will be programmed as
per the Danish regulations
Germany: matches the German regulations
2
The configuration of the pre-sets is available in $8.
Water door
Ext Buzzer
Green lamp
Yellow lamp
:
2
Dual flash light
Doors control
All off
Door 1
OFF
Door 2
OFF
Door 3
OFF
OFF
Oil door
OFF
**********
Confirm
Lamps control
All off
Lamp 1
OFF
Lamp 2
OFF
Lamp 3
OFF
OFF
ON
Red lamp
ON
ON
Gen lamp
ON
**********
Confirm

Interlock

Manual
●●
Denmark
Germany
Default
**********
Confirm