270900_00 | 02.2022
Maintenance and faults
Check the spring steel plates regularly for damage. If cracks or angular
material deformations appear, replace them immediately.
Check the operation of the Titan 80 Pro regularly. To do this, clamp the
housing in a vice and unscrew the wedge as far as it will go. If the
movement of the wedge is stiff, the drive nut must be replaced. The shaft
should turn softly and easily.
In the event of a malfunction, have the device checked by the
manufacturer, a certified workshop or the dealer.
Only use technically flawless original accessories and spare parts.
Decommissioning and disposal
If the Titan 80 Pro is no longer serviceable and is to be scrapped, you
must deactivate and dismantle it, i.e., you must bring the device into a
condition in which it can no longer be used for the purposes for which it
was designed.
The manufacturing company declines all responsibility
i
for any personal injury or damage to property resulting
from the reuse of tool parts if these parts are used for a
purpose other than the original material purpose.