Pin
Source
31
Host
32
Printer
33
34
Printer
35
Printer
36
Host
NC: Not Connected
ND: Not Defined
A signal name with a rule above it indicates an "L" active signal.
Bidirectional communications cannot take place, unless all signal names for both sides
correspond to each other.
CAUTION
Connect all signal lines using a twisted-pair cable. Connect the return side to the signal ground
level.
Make sure the signals satisfy electrical characteristics.
Set the leading edge and trailing edge times to 0.5ms or less.
Do not ignore Ack or BUSY signals during a data transfer. Ignoring such signals may result in
data corruption.
Make the interface cables as short as possible.
NFC Tag
Transmission standard
Frequency
Memory
Transmission distance
When UB-R04 is installed, you cannot use the printer's built-in NFC. Install the NFC tag for the UB-R04
at a location that is remote from the printer's built-in NFC.
The transmission distance is an estimate that depends on our experiment conditions and is not a
guaranteed value.
It varies based on the installation environment and target device.
Compatibility Mode
Init
Init
Fault
DataAvail/Data0,4
GND
ND
DK_STATUS
ND
+5V
ND
SelectIn
1284-Active
ISO14443 A
13.56 MHz
144 byte
Approximately 10 mm from the NFC installation location.
Nibble Mode
Init
DataAvail
ND
ND
ND
1284-Active
Appendix
Byte Mode
133