FUNCTION CODE
03

LOCK OUT COUNT

(Default setting is 03 )
Minimum setting is 1 and Maximum
setting is 9 .
The system will ignore further
keypad code for 90 second if invalid
keypad code has been entered a
specific number of times.
Does not valid for card code or
combination between card code and
keypad code.
04

TONE OR PULSE

(Default setting is TONE)
Always set for TONE, no phone bill
will not work on pulse.
05

SINGLE OR MULTI SYSTEMS

(Default setting is SINGLE)
If more than one systems are on the
same phone line, you must set each
system to MULTI.
Pach and Company
AeGIS NPB9000P Series
Step 4 Enter the unlock time value (04-99 Seconds) then press #, the display shows
Step 5 Select another Function Code to program different field from the table or
press * to exit the programming mode.
Step 1 Log on to programming mode (see section 3.1). The display shows
Step 2 Enter Function code 03, then press #, the display shows
Step 3 Enter the Lock Out Count value (1-9) then press #, the display shows
Step 4 Select another Function Code to program different field from the table or
press * to exit the programming mode.
NOT APPLICABLE FOR NON SUBSCRIBER.
Step 1 Log on to programming mode (see section 3.1). The display shows
Step 2 Enter Function code 05, then press #, the display shows
Step 3 Enter 1 for SINGLE or 0 for MULTI, then press #, the display shows
Chapter 3
PROGRAMMING
LOCAL PROGRAMMING
Page 11