Advertisement

Quick Links

OPERATING MANUAL BDC-655
VERSION 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BDC-655 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blastrac BDC-655

  • Page 1 OPERATING MANUAL BDC-655 VERSION 1.0...
  • Page 2: Ec Declaration Of Conformity

    EC DECLARATION OF CONFORMITY in accordance with Appendix II sub A of Directive 2006/42/EC BLASTRAC B.V. Utrechthaven 12 NL - 3433 PN NIEUWEGEIN Tel: 0031 (0)30 601 88 66 Fax: 0031 (0)30 601 83 33 Info@Blastrac.nl The Netherlands We declare under our sole responsibility that the machine as described below conforms with the Health and Safety requirements of the European Directive for machine Safety.
  • Page 3: Table Of Contents

    Table of contents EC Declaration of Conformity 1. Introduction 2. Machine description 3. Safety Safety precautions - general Safety precautions - with regard to transport Safety regulations – with regard to maintenance 4. Before operation Checkpoints of power supply 5. Operation Starting / stopping the machine Work with the machine Interrupting work...
  • Page 4: Introduction

    Class H13 HEPA filter in accordance with EN1822 Application The BDC-655 is especially designed to be used in combination with Blastrac machines but can also be used with machines from other brands. Contact Blastrac B.V. for the correct execution and combinations.
  • Page 5 Power supply cable Handle dust bin Socket blast machine Filter cartridges & lifting system Control box 10 Connection blast machine Cable support 11 Dust bin Compressor 12 Fan Silencer 13 Air pistol Pulse system complete 14 Motor...
  • Page 6: Safety

     The unit should not be used near flammable gasses or substances.  The BDC-655 must not be applied for carcinogenic or asbestos substances. Do not use the unit when it is damaged.  Do not use damaged extension cables.
  • Page 7 Safety regulations The following sticker is placed on the machine. Meanings of these symbols are: Ear protection is obliged  Safety glasses with lateral protection are obliged  CE-mark on this machine  Safety shoes obliged  Consult the manual before operating the machine ...
  • Page 8: Before Operation

    4. Before operation Before using the machine it is essential to inspect the machine. It is not permitted to use the machine if the machine safety is not according the checkpoints below. Checkpoints of electrical safety Use only extension cables for extending the main cable that are sized and marked in accordance with ...
  • Page 9: Maintenance

    Store the cleaned and dry machine in a dry and humid free room. Protect the electrical motors from moisture, heat, dust and shocks. All repair work must to be done by qualified Blastrac personnel, this to guarantee a safe and reliable machine. Any guarantee on the machine is expired when: Non original Blastrac parts have been used ...
  • Page 10: Filter Replacement

    When there is pressure but the pulse system does not function, there might be a problem in the electrical system which controls the pulsing system. Check the wiring and the PLC-settings. PLC timer unit Advised is to take contact with Blastrac Support in order to prevent operational problems.
  • Page 11: Compressor

    Replacement or cleaning of the air filter of the compressor (item 5 page 5) is depending on the environment in which the Dust collector is operating. Advised is to take contact with Blastrac support in order to prevent operational problems. 7. Technical data BDC-655 5.5 kW...
  • Page 12: Contact

    Headquarter Blastrac Poland Blastrac Italy Blastrac The Netherlands Golina, Dworcowa 47a S.S. 10 Padana Inferiore, 41 Utrechthaven 12 PL – 63-200 Jarocin IT – 29012 Caorso (PC) NL – 3433 PN Nieuwegein Tel – 0048 627 40 41 50 Tel – 0039 0523 81 42 41 Tel –...

Table of Contents