3 Functionality and Interfaces

Supply Voltage
Motor Supply 3x400 VAC / 3x480 VAC
Logic Supply 24VDC (22...26VDC)
Motor Phase Current (preliminary)
28A
(0-500Hz)
rms peak
4 A
(0-500Hz) (without forced cooling)
rms continuous
12 A
(0-500Hz) (with fan option EV01-E1400)
rms continuous
18 A
(0-500Hz) (cold plate 20°C)
rms continuous
Controllable Motors
LinMot P10-70x...(Motor Link C)
Selected motors (contact support)
Command Interface
CANopen
LinRS
POWERLINK
PROFINET
SERCOS III
ETHERNET IP
LinUDP
ETHERCAT
PROFIBUS-DP
Programmable Motion Profiles (Curves)
Up to 99 Motion Profiles
Up to 16302 Curve Points
Programmable Command Table
Command Table with up to 255 entries
External Position Sensor
Incremental (RS422 up to 25 M counts/s)
SinCos (1Vpp differential)
Absolute (SSI)
Synchronisation
Master Encoder In/Out (RS422 up to 25 M counts/s)
Configuration Interface
RS232
Ethernet 10/100 Mbit/s (2-Port Switch integrated)
Integrated Safety Functions (-1S Option)
STO (2 Safety Relays)

4 IP Address Selection

The default mode for acquiring an IP address is via DHCP. If no servers respond on
the connected network, the drive switches to the IPv4 Link-Local addressing
scheme (also known as APIPA on Windows systems). This way the drive
automatically assigns itself an address within the range of 169.254.0.1 through
169.254.255.254 (Subnet Mask 255.255.0.0).
Please note that this process can take up to a minute until a valid address is
assigned to the drive.