<Menu management accompanying switching the system frequency>
The system menu and setup menu have some items whose settings differ and other items with which no
selection options are displayed and whose settings are fixed (indicated by the shading in the table below),
depending on the switching of the operation mode in response to the setting selected for system menu item
No.25 (SYSTEM FREQ). (Refer to the table below.)
System menu and setup menu settings
• Each of the items whose settings differ is saved in
the VTR MEMORY (current file and one of the
backup files 1 to 4). The settings that correspond to
each operation mode will be displayed so that the
settings can be performed for each operation mode.
Registration of the <PF1> and <PF2> function
buttons
• When the items whose settings differ have been
registered in the <PF1> and <PF2> function buttons,
the settings that correspond to each operation mode
will be displayed so that the settings can be performed
for each operation mode.
• If items, whose selection options are not displayed due
to the operation mode, have been registered in the
<PF1> or <PF2> function button, when an operation
mode in which these options are not displayed is
selected, what has been registered is saved but the
function button itself will become blank and cannot be
operated. Bear in mind, however, that when the data is
registered again, it is saved by overwriting the existing
data so that the previously registered data will be lost.
System menu
No.
Menu item
12
SYS H (HD)
14
SYS SC (SD)
15
VO SYS H (SD)
16
SD SYS D (SD)
Setup menus
No.
Menu item
109
CAP.LOCK
501
VITC POS-1
502
VITC POS-2
600
VIDEO IN SEL
The underlining (__) denotes the factory setting mode.
(Continued on next page)
106
59/60
COARSE
j5H to 0H to 5H
FINE
j1100 to 0 to 1100
j108 to 0 to 108
COARSE
j5H to 0H to 5H
FINE
j858 to 0 to 858
COARSE
j5H to 0H to 5H
FINE
j858 to 0 to 858
59/60
2F/4F
10L to 16L to 20L
10L to 18L to 20L
INTSG
HDSDI
SDTI
SDSDI
<50P IN/OUT> 50-pin connector registration
• When the items whose settings differ have been
registered in the <50P IN/OUT> 50-pin connector
pins, the settings corresponding to the operation
modes are allocated to the IN and OUT pins on the
basis of the setting numbers. However, when the
upper limit value is exceeded, the value will be
limited to this upper limit.
What has been registered is saved, but bear in mind
that when the data is registered again, it is saved by
overwriting the existing data so that the previously
registered data will be lost.
• If items, whose selection options are not displayed
due to the operation mode, have been registered in
the <50P IN/OUT> 50-pin connector, when an
operation mode in which these options are not
displayed is selected, what has been registered is
saved but no operation is possible. Bear in mind,
however, that when the data is registered again, it is
saved by overwriting the existing data so that the
previously registered data will be lost.
System menu No.25 (SYSTEM FREQ)
23/24
50
j5H to 0H to 5H
j1375 to 0 to 1375
System menu No.25 (SYSTEM FREQ)
23/24
50
2F
2F/4F/8F
7L to 11L to 22L
7L to 13L to 22L
INTSG
HDSDI
SDSDI
25 (HD)
25 (SD)
j5H to 0H to 5H
j1320 to 0 to 1320
j115 to 0 to 115
j5H to 0H to 5H
j864 to 0 to 864
j5H to 0H to 5H
j864 to 0 to 864
25 (HD)
25 (SD)
2F
2F
7L to 11L to 22L
7L to 13L to 22L