Disposal - WAGNER AirCoat GM 4100 AC Operating Manual

Manual gun for flat and round jet nozzles
Table of Contents

Advertisement

VERSION 01/2018
Activity
4. Checking the switching sequence
– Attach the AC nozzle and air cap.
– Set the injection pressure to 100 bar; 10 MPa; 1450.40 psi, pull the trigger
slowly, note the switching sequence "switch on" and "switch off".
Switch on: atomizing air / shaping air on, product on
Switch off: product off, atomizing air / shaping air off
5. Flush the spray gun
– Switch off the air and product supply, open flushing valve, pull trigger
lever and flush gun or blow out with air.
Flush the gun without the valve and air cap.
In doing so, you can remove the air connection hose.
– Close the flushing valve. When almost no more product comes out,
remove the product connection hose and blow the rest of the test
medium out of the spray gun using an air gun.

12 DISPOSAL

When the equipment must be scrapped, please differentiate the disposal of the waste
materials.
The following materials have been used:
– Stainless steel
– Aluminum
– Elastomers
– Plastic
– Carbide
The consumable products (lacquers, adhesives, solvents) must be disposed of in accordance
with the applicable specific standards.
ORDER NUMBER DOC 394821
Means
Visual inspection
39

Advertisement

Table of Contents
loading

Table of Contents