Battery Temperature Sensor Installation And Wiring; Figure 2-9, Battery Temperature Sensor - Sensata Magnum Energy MS Series Owner's Manual

Pure sine wave inverter/charger
Table of Contents

Advertisement

2.4.5

Battery Temperature Sensor Installation and Wiring

The Battery Temperature Sensor (shown in Figure 2-9) provides the inverter with precise battery
temperature information to automatically adjust the ABSORB and FLOAT charge voltage set-points.
This allows the batteries to be correctly charged under extreme temperature changes.
If the temperature sensor is NOT installed and the batteries are subjected to large temperature
changes, the battery life may be shortened. The BTS cable may be extended—using a RJ11
connector (female to female) and a standard phone cable with RJ11 connectors—to a maximum
length of 40 feet (12 m). However, your inverter to battery cable length should not exceed the
recommended distance provided in Table 2-2.
To install the BTS:
1. Attach the ring terminal end of the Battery Temperature Sensor to the negative battery terminal;
see Figure 2-7 for proper connection to the battery terminal.
2. Route the sensor's cable to the inverter following existing wire runs.
3. Connect the RJ11 connector end of the BTS cable to the yellow-labeled BTS port on the inverter
(Figure 1-1, Item 6).
Cable
Cable
© 2016 Sensata Technologies
FRONT VIEW
~2"
(~5.1 cm)
SIDE VIEW

Figure 2-9, Battery Temperature Sensor

~1"
(~2.54 cm)
~¾"
(~1.9 cm)
0.375" diameter
(~.95 cm)
~½"
(~1.3 cm)
Installation