Appendix A - Specifi Cations And Optional Equipment; Inverter/Charger Specifi Cations - Sensata Magnum Energy MS Series Owner's Manual

Pure sine wave inverter/charger
Table of Contents

Advertisement

Appendix A – Specifi cations and Optional Equipment
A-1 Inverter/Charger Specifi cations
Inverter Specifi cations
Input battery voltage range
Absolute maximum DC input
AC output voltage accuracy
Output frequency and accuracy
Total Harmonic Distortion (THD)
Continuous power output (at 25°C)
Continuous AC output current
1 msec surge current (amps AC)
100 msec surge current (amps AC)
5 sec surge power (real watts)
30 sec surge power (real watts)
5 min surge power (real watts)
30 min surge power (real watts)
Maximum continuous input current
Inverter effi ciency (peak)
HBCO/HBCI (High Battery Cut Out/In)
LBCO/LBCI (Low Battery Cut Out/In)
AC Relay transfer time (minimum)
Power consumption – searching
Power consumption – inverting (no load)
Output waveform
Charger Specifi cations
Continuous charger output at 25°C
Input current for continuous rated output
Charger effi ciency
AC input range (frequency/voltage)
Power factor
General Features and Capabilities
Transfer relay capability
Five-stage charging capability
Battery temperature compensation
Internal cooling
Overcurrent protection
Over-temperature protection
Corrosion protection
Safety listings
Warranty
Branch-rated output circuit breakers
Environmental Specifi cations
Temperature (Operating/Non-operating)
Operating humidity
Physical Specifi cations
Unit dimensions (length x width x height)
Shipping dimensions (L x W x H)
Mounting
Unit weight
Shipping weight
Max operating altitude
** The pass-thru capability on each leg of the – 15B and – 20B models is limited by the output breaker size on each output.
ETL listed to UL/cUL 458, CSA C22.2 No. 107.1-01, and meet KKK-A-1822E standard.
*** MS2000 models
Specifi cations @ 25°C – Subject to change without notice.
© 2016 Sensata Technologies
MS2000/12
Models
MS2012 ( -15/-20B)
9.0 to 16.8 VDC
25 VDC
2000 VA
17 A
50
33
3300
3100
2800
2200
267 ADC
90.6%
16.8/16.5 VDC
9.0 (adj)/12.5 VDC
25 watts
100 ADC
15 AAC
30AAC max. each input (30AAC total on MS2000 models, 60AAC total on all other models)**
Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Standard with available temp sensor connected (battery temp 0 – 50°C)
0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan
PCB's conformal coated, powder coated chassis/top, and stainless steel fasteners
ETL listed to UL/cUL 458, UL 1741, CSA C22.2 No. 107.1-01, and meets KKK-A-1822E std.***
Optional on MS2000 (15 or 20 amp breakers) or MS2012 (15 or 20 amp breakers)
-20°C to +60°C (-4°F to 140°F)/-40°C to +70°C (-40°F to 158°F)
13.75" x 12.65" x 8.0" (34.9 cm x 32.1 cm x 20.3 cm) [Height on MS2000 models is 7.0"/17.8 cm]
Shelf or wall (vents not allowed to face downward unless ME-CB or MMP/MP is installed)
42 lb (19.1 kg)
48 lb (21.8 kg)
Appendix A – Specifi cations
MS2812
MS2024
18.0 to 33.6 VDC
120 VAC ±5% (≤ continuous power)
60 Hz ± 0.1 Hz
< 5%
2800 VA
2000 VA
23 A
17 A
70
75
40
37
3900
2850
3800
2750
3200
2700
3000
2200
373 ADC
133 ADC
90%
86%
33.6/33.0 VDC
18.0 (adj)/25.0 VDC
16 msec
<8 watts
30 watts
Pure Sine Wave
125 ADC
60 ADC
18 AAC
7.9 AAC
85%
50 to 70 Hz/ 60 to 140 VAC (120 VAC nominal)
> 0.95
with two overlapping circuits
on transformer, MOSFETS, and battery
3 years parts and labor
0 to 95% RH non-condensing
19" x 17" x 13" (48.3 cm x 43.2 cm x 33 cm)
55 lb (24.9 kg)
41 lb (18.6 kg)
62 lb (28.1 kg)
49 lb (22.2 kg)
15,000' (4570 m)
MS4048
MS4024
MS4048-20B
36.0 to 67.6 VDC
35 VDC
4000 VA
4000 VA
33 A
120
82
72
5800
8500
5400
5750
4900
5250
4500
4750
267 ADC
133 ADC
93.7%
94.0%
67.6/66.7 VDC
36.0 (adj)/50.0 VDC
25 watts
105 ADC
60 ADC
29 AAC
30 AAC
55 lb (24.9 kg)
55 lb (24.9 kg)
62 lb (28.1 kg)
62 lb (28.1 kg)