Wiring The Battery Bank; Figure 2-7, Battery Hardware Installation; Figure 2-8, Inverter Dc Hardware Installation - Sensata Magnum Energy MS Series Owner's Manual

Pure sine wave inverter/charger
Table of Contents

Advertisement

Installation
nut
split washer
CAUTION:
Ensure nothing is
placed between
the cable ring lug
and battery post.
Figure 2-7, Battery Hardware
Installation
2.4.4

Wiring the Battery Bank

WARNING: Lethal currents will be present if the positive and negative cables attached
to the battery bank touch each other. During the installation and wiring process, ensure
the cable ends are insulated or covered to prevent touching/shorting the cables.
Info: DO NOT connect the DC wires from the battery bank to the inverter until 1) all DC
and AC wiring is complete, 2) the correct DC and AC overcurrent protection has been
installed, and 3) the correct DC voltage and polarity have been verifi ed.
Info: For the MS Series inverter/charger to perform optimally, a minimum battery bank
of 200 AH is recommended for moderate loads (<1000W) and greater than 400 AH for
heavy loads (≥1000W).
Depending upon the voltage of the batteries you use in the installation (6 or 12 VDC), the batteries
must be wired in series, parallel, or series-parallel to provide the correct voltage (see Appendix
B – Battery Information for guidance on wiring batteries together). The interconnecting DC wires
must be sized and rated exactly the same as those used between the battery bank and the inverter.
Place the batteries as close as practical to the inverter, preferably in an insulated and ventilated
enclosure. Allow adequate space above the batteries to access the terminals and vent caps (as
applicable). Also, allow at least 1" (2.5 cm) of space between the batteries to provide good air
fl ow. DO NOT mount the batteries directly under the inverter.
CAUTION: Install batteries in a well ventilated area. Batteries can produce explosive
gasses. For compartment or enclosure installations, always vent batteries to the outside.
Info: To ensure the best performance from your inverter system, batteries should be
of the same size, type, rating, and age. Do not use old or untested batteries.
Page 19
Battery
Temperature
Sensor
battery cable
(with ring lug)
battery
post
placed between the DC
terminal and ring lug.
Inverter DC terminal
(
5/16–18 bolt,
)
5/8" usable length
battery cable
(with ring lug)
Figure 2-8, Inverter DC Hardware
Installation
© 2016 Sensata Technologies
CAUTION:
Ensure nothing is
5/16-18
Flange or
Kep nut

Advertisement

Table of Contents
loading