Installation - Sensata 24TX60 Owner's Instructions Manual

Dc to ac power inverters quasi-sine wave 3-phase output
Table of Contents

Advertisement

6 Installation

6.1 Tools for Installation:
Tools required for installation: 3/4" socket wrench, connectors (butt type and insulated), drill, Crimpers (for
insulated and non-insulated connectors), volt meter with probes, electrical tape, #2 Phillips screwdriver,
wire cutters, wire strippers, cable ties, and a tape measure.
6.2 Mounting the inverter:
The inverter mounting location should provide adequate ventilation and clearance to maintain
room temperature during operation. At least 1/2 inch of clearance is required on all sides.
 Locate a suitable, secure vertical or horizontal mounting surface as close to the batteries as
possible without being in the same airtight compartment.
 If mounting the inverter on a vertical surface, it is recommended that the front control panel
be pointing down whenever possible.
 Locate the mounting holes on the chassis flanges and fasten them using ¼ inch diameter
screws to secure the inverter. See figure 5.
6.2.1
The following instructions should be thoroughly read and understood before installation.
6.2.2 CAUTION: Inverters produce hazardous voltage, and to avoid risk of harm or fire the unit must be
properly installed.
CAUTION: The inverter should not be mounted in a location that may be exposed to rain or spray.
CAUTION: The inverter should not be installed in a zero clearance enclosure.
CAUTION: When working near batteries, safety goggles should be worn.
CAUTION: Be sure the inverter is turned "OFF" during installation.
National Electric Code, provincial or other codes in effect at the time of installation, regardless of
suggestions in this manual. All wires should be copper conductors.
Form: 122189 © 2012 Sensata Technologies
Figure 5 (Inverter Footprint)
9
NOTE: All wiring must follow the

Advertisement

Table of Contents
loading

Table of Contents