—40%
•
—50%
Dark Set options:
•
—minimum
•
—25%
•
—50%
•
—100%
•
—200%
3.1.4 Response Speed
Use this menu to select the response speed. The default is 1 millisecond.
•
—250 microseconds
•
—1 millisecond
•
—5 milliseconds
Table 1: Tradeoffs
Response Speed
250 µs
1 ms
5 ms
25 ms (Master-Slave Sync)
3.1.5 Output Timing Delays
Use this menu to select the output timing delay to be set. Only one delay type can be used at a time. The default is no delay.
•
—No delay
•
—Enables simultaneous on and off delay timers
•
—One-shot. Enables a one-shot, fixed output pulse duration
Output
OFF Delay
ON Delay
1-Shot
When either
or
timer(s):
•
—On delay
Repeatability
Crosstalk Immunity
60 µs
Disabled
300 µs
Enabled
520 µs
Enabled
Best for direct line of sight
13 ms
crosstalk
D
D
Figure 6. Output Timing Delays
is chosen, the sensor returns to the Setup menu and additional options become available to set the
www.bannerengineering.com - Tel: 763.544.3164
D
D
D
Time
Q3X Laser Contrast Sensor
High Efficiency Light Rejection
Disabled
Disabled
Enabled
Enabled
ON
OFF
D
(D = 1ms - 90.0s)
9