Teach Menu; Response Speed; Output Timing Delays - Banner q4x Instruction Manual

Stainless steel laser sensor
Hide thumbs Also See for q4x:
Table of Contents

Advertisement

Q4X Stainless Steel Laser Sensor

3.2.1 TEACH Menu

Use this menu to select the TEACH mode. The default is two-point TEACH.
—Two-point static background suppression
—Dynamic background suppression
—One-point window (foreground suppression)
—One-point background suppression
After the TEACH mode is selected, from Run mode, press and hold TEACH for longer than 2 seconds to start the TEACH
mode and program the sensor. See
instructions.

3.2.2 Response Speed

Use this menu to select the response speed. The default is 10 milliseconds.
—1.5 milliseconds
—3 milliseconds
—10 milliseconds
—25 milliseconds
—50 milliseconds
Table 1: Tradeoffs
Response Speed
Response Speed in
Sync Mode
1.5 ms
3 ms
3 ms
6 ms
10 ms
20 ms
25 ms
50 ms
50 ms
100 ms
Gain and Sensitivity
Use this menu to set the excess gain mode. This menu is only available when a 10, 25, or 50 millisecond response speed is
selected. It is not available for 1.5 or 3 millisecond response speeds.
—High excess gain mode
—Standard excess gain mode with increased noise immunity

3.2.3 Output Timing Delays

Use this menu to select the output timing delay to be set. On and off delay timers can be used together. The default is no
delay.
—No delay
—Delay—enables the selection of on and off delay timers
—One-shot—enables a one-shot, fixed output pulse duration
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
TEACH Procedures
on page 15 for additional information and remote input TEACH
Repeatability
500 µs
500 µs
2 ms
5 ms
10 ms
Ambient Light
Excess Gain
Rejection
Disabled
Enabled
Enabled
See
Enabled
Enabled
Table 7
on page 22