The following LEDs must light after switching on:
Receiver
Status
Ready for operation
Transmitter
Status
Safety light curtain in operation
Transmitter sends uncoded
Safety light curtain in operation
Transmitter sends A-coded
Safety light curtain in operation
Transmitter sends B-coded
Check whether the coding corresponds to the specifications in
cent safety light curtains [
Check the
tain.
Interrupt the protected field. The following LED must light at the receiver:
green
green

Check after plant/machine modification

Check the safety light curtain each time the plant/machine is modified.
The following measures should also be regarded as a modification:
}
The exchange of the safety light curtain
}
The exchange of components of the safety light curtain
}
A changed connection of the safety light curtain (change from uncoded connection to
coded connection).
You must comply with the requirements of the applicable national regulations.
Operating Manual PSEN opII3B Series
1004845-EN-02
green
green The current reception quality status
20].
pin assignment [
29], when other displays can be seen at the safety light cur-
red
green
red
green
is indicated.
green
green
green
green
green
green
Protected field is interrupted,
A-coded
Protected field is interrupted,
B-coded
green
green
Installation of several adja-
Meaning
| 39

Advertisement

Table of Contents
loading

Table of Contents