PSEN opII3B Series
Mechanical data
Max. torque setting
Clamping screw
Installation screw
Fixing screw
Dimensions
Height
Width
Depth
Weight
Where standards are undated, the 2015-12 latest editions shall apply.
Classification according to ZVEI, CB24I
The following tables describe the classes and specific values of the product interface and
the classes of interfaces compatible with it. The classification is described in the ZVEI posi-
tion paper "Classification of Binary 24 V Interfaces - Functional Safety aspects covered by
dynamic testing".
Safe 1-pole HL outputs
Source
Safety switch
Source parameters
Test impulse duration
Rated current
Capacitive load
Safety characteristic data
Operating
EN ISO
mode
13849-1:
2015
PL
Sensor, 2-
channel
PL d
Explanatory notes for the safety-related characteristic data:
Operating Manual PSEN opII3B Series
1004845-EN-02
632113
1,1 Nm
3 Nm
0,7 Nm
904 mm
35 mm
40 mm
2.618 g
C2
Min.
-
-
-
NOTICE
You must comply with the safety characteristic data in order to achieve the
required safety level for your plant/machine.
EN ISO
EN 62061
13849-1:
SIL CL
2015
Category
Cat. 3
SIL CL 2
632114
1,1 Nm
3 Nm
0,7 Nm
1.204 mm
35 mm
40 mm
3.420 g
Drain
Evaluation device
Typ.
-
-
-
EN 62061
IEC 61511
PFH
[1/h]
SIL
D
2,00E-07
–
632115
1,1 Nm
3 Nm
0,7 Nm
1.504 mm
35 mm
40 mm
4.221 g
C1, C2
Max.
300 µs
0,1 A
40 nF
IEC 61511
EN ISO
13849-1:
PFD
2015
T
[year]
M
2,00E-03
20