Orientation

General guidelines

For the safety light curtain to function properly, the transmitter and receiver must be aligned
correctly.
The safety light curtains transmitter and receiver can be oriented with or without a laser ori-
entation aid.
}
Orientation with a laser orientation aid: the safety light curtain need not be switched on
}
Orientation without a laser orientation aid: the safety light curtain must already be wired
(see chapter entitled "Wiring" in the safety curtain's operating manual) and must be
switched on
Operating Manual PSEN opII3B Series
1004845-EN-02
Fix the transmitter and receiver and their flexible
brackets in place on the installation surface.
For each bracket, use two mounting screws with wash-
ers [1]
included in delivery [
ing screws with deviating lengths can be used.
Transmitters and receivers can be shifted vertically
[1]
and horizontally.
Screws are only tightened to the final torque during
alignment.
Ensure that the transmitters and receivers are properly
installed in a suitable place.
Ensure that the transmitters and receivers are posi-
tioned at the same height and parallel to one another.
9]. If necessary, mount-