SECTION 5 - JLG CONTROL SYSTEM

Using the Analyzer:

With the machine power on and the analyzer connected
properly, the analyzer will display the following:
M ENU:
HELP:PRESS ENTER
HELP:
PRESS ENTER
At this point, using the RIGHT and LEFT arrow keys, you
can move between the top level menu items. To select a
displayed menu item, press ENTER. To cancel a selected
menu item, press ESC; then you will be able to scroll
using the right and left arrow keys to select a different
menu item.
The top level menus are as follows:
HELP
DIAGNOSTICS
ACCESS LEVEL
PERSONALITIES
MACHINE SETUP
ACTIVATE TESTS
CALIBRATION
If you press ENTER, at the HELP:PRESS ENTER display,
and a fault is present, the analyzer display will scroll the
fault across the screen. If more than one fault is present
only the highest priority fault will show. The other active
faults are viewable in Logged Help. If there was no fault
detected, the display will read:
In platform mode,
HELP: (001)
EVERYTHING OK,
In ground mode,
HELP: (002)
GROUND MODE OK
5-2
If ENTER is pressed again, the display moves to the fol-
lowing display:
HELP:
1:STARTUP ( 2/ 1)
(machines with no MDI)
LOGGED HELP
1: STARTUP (2/1): (Or last recorded fault)
LOG: (211)
1: Power Cycle (Or last recorded fault)
At this point, the analyzer will display the highest prior-
ity active fault, if any are present. You may scroll through
the fault logs to view what the last fifteen faults were.
Use the right and left arrow keys to scroll through the
fault logs. The active faults, are listed before the first
POWER CYCLE. To return to the top menu, press ESC two
times.
When a top level menu is selected, a new set of menu
items may be offered; If for example you choose Person-
alities:
DRIVE
LIFT
STEER
GROUND
Pressing ENTER with any of the above displayed menus,
will display additional sub-menus within the selected
menu. In some cases the next level is the parameter or
information to be changed. Refer to the flow chart for
what menus are available within the top level menus.
You may only view the personality settings for selected
menus while in access level 2. Remember, you may
always cancel a selected menu item by pressing the ESC
key.
l og:
( 211)
or
(machines with an MDI)
3121656