Parameter
Alarm Out
Latch
Show Message
Send Email
Buzzer
Log
Post Record
Voice Prompts
Step 3
Click Apply to complete the settings.
5.10.5.3 Configuring User Event Settings
Step 1
Select Main Menu > ALARM > ABNORMITY > User.
The User interface is displayed. See Figure 5-138.
Description
Click Setting to display setting interface.
General Alarm: Enable alarm activation through the alarm devices
connected to the selected output port.
External Alarm: Enable alarm activation through the connected
alarm box.
Wireless Siren: Enable alarm activation through devices
connected by USB gateway or camera gateway.
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 10 seconds to 300
seconds, and the default value is 10 seconds.
Select the Show Message check box to enable a pop-up message in
your local host PC.
Select the Send Email check box to enable the system to send an
email notification when an alarm event occurs.
To use this function, make sure the email function is enabled in Main
Menu > NETWORK > EMAIL.
Select the check box to activate a buzzer noise at the Device.
Select the check box to enable the Device to record a local alarm log.
Continue to record for some time after the alarm is ended. The value
ranges from 10 seconds to 300 seconds.
Select to enable audio broadcast/voice prompts in response to a
network alarm event.