Mounting the Device

Mounting the
Device
CAUTION
NOTE
To mount the unit
NOTE
NOTE
Using the Smart
Card Reader
18
UX700 I
NSTALLATION
Use the following procedure to mount the UX700 to a suitable mounting surface.
Make sure that your mounting frame has a thickness of 2 mm.
Your mounting surface may have different installation instructions. Refer to the
user guide of your mounting device for further information.
1
Align the UX700 stud holes with the holes on the mounting surface.
Figure 6
Mounting the UX700
2
Place the reader flush onto the mounting slot.
3
Secure the unit with M5 nuts with a minimum length of 12 mm. Tighten the
nuts using the recommended torque of 7.0 kg-cm (6.1 lbf.in).
You can also mount the UX700 using welded screw bolts on the inner side of the
mounting plate. This prevents any vandalism of the screw heads on the outer
surface.
4
Connect flexible tubing with 9mm inner diameter to the drain nozzle at the
bottom of the UX700 and place the other end of the tubing at an appropriate
drainage area.
The nozzle drains water out of the bezel area through the flexible tube. Ensure
that the tubing is properly dressed and mounted as vertical as possible (without
any loops) to ensure smooth water drainage.
Insert the smart card to proceed with the EMV transaction. EMV supports credit
card and debit card transactions.