Lock Relay Connection - ZKTeco SilkID F21-ID Installation Manual

2.4 inch tft terminal time attendance & access control
Table of Contents

Advertisement

15

Lock Relay Connection

Device does not Share Power With The Lock
485B
485A
GND
TXD
RXD
GND
WD1
WD0
PIN DESCRIPTION WIRE
1 AL+
Red
2 AL-
Black
3 NC1
Gray
4 COM1
Black
5 NO1
White
6 BUT
Blue
7 GND
Red
8 SEN
Yellow
9 BELL+
Orange
10 BELL-
Green
11
GND
Purble
12
Aux
Brown
Do not use
Notes:
1. The system supports NO LOCK and NC LOCK. For example the NO LOCK (normally open
at power on) is connected with 'NO1' and 'COM1' terminals, and the NC LOCK (normally close
at power on) is connected with 'NC1'and 'COM1' terminals.
2. When electrical lock is connected to the Access Control System, you must parallel one FR107
diode (equipped in the package) to prevent the self-inductance EMF a ecting the system.
!
Do not reverse the polarities.
2.4 Inch TFT Time Attendance & Access Control Terminal INSTALLATION GUIDE
1
COM1
12V DC
GND
12V DC Adaptor
12
Sensor
GND
NC1
-
FR107
Diode
Normally Closed Lock
Device Shares Power With The Lock
485B
485A
GND
TXD
RXD
GND
WD1
WD0
PIN DESCRIPTION WIRE
1 AL+
Red
2 AL-
Black
3 NC1
Gray
4 COM1
Black
5 NO1
White
6 BUT
Blue
+
7 GND
Red
8 SEN
Yellow
9 BELL+
Orange
10 BELL-
Green
11
GND
Purble
12
Aux
Brown
Do not use
1
COM1
12V DC
12
GND
NC1
Sensor
Normally Closed Lock
2.4 Inch TFT Time Attendance & Access Control Terminal INSTALLATION GUIDE