Specifications - Greenlee CMPL-100 Instruction Manual

Clamp-on meter
Table of Contents

Advertisement

Available languages

Available languages

Specifications

Display: 4-digit LCD (9999 maximum reading) and 40-segment bar graph
Sampling Rate:
Numeric Display: 2 per second
Bar Graph Display: 10 per second
Continuity Indication: Buzzer sounds for resistance less than 100
Diode and Continuity Modes:
Open Circuit Voltage: 4.5 V typical
Test Current: 1.0 mA typical
Resistance Mode:
Open Circuit Voltage: 4.5 V typical
Test Current: 0.1 mA typical
Automatic Power-Off: After 20 minutes of inactivity
Over Range Indication: OL appears on the display (except for ranges of 1000 A
and 1000 VDC and 750 VAC)
Jaw Opening: 46 mm (1.811'')
Overvoltage Category: Category III, 600 Volts
Operating Conditions: 0 C to 40 C (32 F to 104 F), 0% to 80% relative humidity
(non-condensing)
Indoor use only
Elevation: 2000 m (6500') maximum
Storage Conditions: –10 C to 60 C (14 F to 140 F), 0% to 70% relative humidity
(non-condensing)
Remove battery.
Pollution Degree: 2
Battery: 9-Volt battery (NEDA 1604, JIS 006P or IEC 6LF22)
20
10%

Advertisement

Table of Contents
loading