9. eRROR CODeS

During the meter operation, error messages may be
displayed. following list shows causes of particular errors.
- Err1 – too low voltage or current during measurement:
- bAd Freq – during THD measurement, when frequency value
is outside 48 – 52 Hz range for 50Hz and outside
58 – 62 Hz range for 60 Hz;
- Err bat – internal RTC battery. The measurement is carried out
after switching the supply on and every day at midnight.
Then the message may be turned off by pressing
the button. Then the message will be inactive until
the meter is turned off and on again;
- Err CAL, Err EE – meter memory damaged. In such case meter
should be sent back to the manufacturer.
- Err PAr – incorrect operational parameters of the meter.
In such case meter should be set to default (factory)
settings (from menu or via RS-485 interface). Message
can be disabled by pressing button.
- Err Enrg – incorrect energy parameters. Message can be
disabled by pressing button. Incorrect energy values are
set to 0.