4015
RW
4016
RW
4017
RW
4018
RW
4019
RW
4020
RW
4021
RW
4022
RW
4023
RW
4024
RW
4025
RW
4026
RW
4027
RW
4028
RW
4029
RW
4030
RW
4031
RW
0.1...35
0..5
-1440...0...1440
[
/
]
o
oo
-1440...0...1440
[
/
]
o
oo
0...900 s
0.1
0...900 s
0.1..35
0..5
-1440...0...1440
[
/
]
o
oo
-1440...0...1440
[
/
]
o
oo
0...900 s
0.1
0...900 s
5000 ... 20000
1..247
0..3
quantity on the relay output of
alarm 1 (code as in Table 6)
Output type 1: 0 – n-on, 1– n-off,
2 – on, 3 – off, 4 – H-on,
5 – H-off
Lower value of the alarm 1 switch
of the rated input range
upper value of the alarm 1 switch
of the rated input range
Alarm 1 switch delay value
(for AL_n = P_ord – register 4015
= 35, delay occurs only at alarm
activation)
Alarm 1 signalization latch
Alarm 1 re-activation block
quantity on the relay output of
alarm 2 (code as in Table 6)
Output type 1: 0 – n-on, 1– n-
off, 2 – on, 3 – off, 4 – H-on,
5 – H-off
Lower value of the alarm 2
switch of the rated input range
upper value of the alarm 2 switch
of the rated input range
Alarm 2 switch delay value (for AL_n
= P_ord – register 4015 = 35, delay
occurs only at alarm activation)
Alarm 2 signalization latch
Alarm 2 re-activation block
No. of impulses for the impulse
output
MODBuS Network Address
Transmission mode: 0->8n2,
1->8e1, 2->8o1, 3->8n1
24
0
990
1010
0
0
0
24
0
990
1010
0
0
0
5000
1
0
35

Advertisement