Emerson M200-01200024A10101AB100 Quick Start Manual page 18

Frame sizes 1 to 4
Table of Contents

Advertisement

Figure 4-8 Pr 00.005 = AI.Pr (60 Hz)
Current speed
reference input
Figure 4-9 Pr 00.005 = Preset (50 Hz)
*Refer to Drive User Guide.
18
1
0V
Current speed reference
2
input (AI 1)
4
+ 10 V output
5
Reference select
Analog output 1
7
(motor frequency)
+ 24 V output
9
Digital output
10
(zero frequency)
Not stop
11
12
Run
Jog forward
13
Reference select
14
1
0V
Voltage speed reference
2
input (AI 1)
4
+ 10 V output
5
Reference select
Analog output 1
7
(motor frequency)
+ 24 V output
9
Digital output
10
(zero frequency)
Drive enable
11
12
Run forward
Run reverse
13
Reference select
14
Terminal 5 Terminal 14
0
0
Analog reference 1*
0
1
Preset speed 2*
1
0
Preset speed 3*
1
1
Preset speed 4*
Terminal 5 Terminal 14
0
0
Preset speed 1*
0
1
Preset speed 2*
1
0
Preset speed 3*
1
1
Preset speed 4*
Unidrive M200-201 Quick Start Guide
Reference selected
Reference selected
Issue Number: 6