• The basic position information per rotation for the servo amplifier is 26 bit (67108864 pulse).
Program
The Motion module performs control with the buffer memory instead of using the XY signal for the PLC READY, servo ON
command, and start command. In addition, the I/O No. starts from 1. In the program below, PLC READY of Start I/O No. 1
Motion module is turned ON and the servo ON of the axis used can be executed.
Downloaded from
ManualsNet.com
search engine
Appendix 9 Setting Example for Motion Modules (FX5-SSC-G)
When "Load Side Encoder Information"
When "Load side encoder information"
is retrieved in the optional data monitor.
is retrieved in the optional data monitor.
APPX